Fastwarm™ Clip Track Standard Output Water Underfloor Heating Kits are designed for installation in areas such as conservatories or rooms with multiple external walls and lots of glass etc as pipe centres are @ 250mm spacings. When heating rooms with higher heat loss, our high Output systems are more suitable (200mm spacing)
Fastwarm™ Clip Track Standard Output Single Zone systems are designed for use in one Zone (area) and come with only one thermostatic controller - meaning, regardless of how big the area/how many rooms, the system will act as a single unit and be controlled as one zone. For multiple room or zone control we offer the Fastwarm™ Multi Zone systems
Utilising Fastwarm 1m Clip Track this option provides a easy to install fixing track where insulation may be at less of a depth. Each clip in which pipe is inserted is spaced at 50mm interval making this and ideal solution for in screed applications.
Fastwarm™ Water Underfloor Heating systems are the homeowner and installers perfect choice as each kit comes complete with everything you need for installation. With several choices for thermostat control, the system offers great options for all. Systems come with easy-to-follow installation guides and all pipework carries our lifetime warranty (50yr). We have a fully qualified technical support team on stand by ready to take you're call to assist with any installation queries or technical questions.
Fastwarm™ Clip Track Standard Output Water Underfloor Heating Kits are designed to cover the m2 in pipework when spaced at 250mm spacings.
Fastwarm™ Water Kits include FastWarm™ branded products including pipework, pump, thermostats, and manifolds guaranteeing our seal of quality. This component brand control ensures the lifetime guarantee that comes with Fastwarm™ systems. Many similar systems available on the market are simply unbranded or compiled from OEM parts and therefore cannot offer this same quality control.
Fastwarm™ Standard Output Clip Track kits include the following: -
Fastwarm™ Clip Rail
For quickly installing 16mm pipe in any configuration.
Fastwarm™ Pert Al Pert 5 Layer Pipework
Includes 50 year lifetime guarantee
Fastwarm™ Manifold
if 37m2 and above
Grundfos A Rated Pump & Mixing Valve Unit
The ESBE compact T4 thermostatic 4-port pump set is suitable for a maximum output of 18kW.
Choice of Thermostat
We have several thermostats available to fit your budget and lifestyle.
Fastwarm™ Edge Insulation
To be used around the edge of the room to comply with Building Regulations. Dimensions: 8mm x 150mm x 25m
Fastwarm™ Pipe Cutter
Suitable for PVC, PP, PPR and PE pipe. Ideal for fitting MDPE and PEX pipes. Cutting capacity 36mm.
Kit Content Comparison Table
This table shows exactly what you'll get in the box based on your chosen kit size.
Kit Size (m2) | 12 | 15 | 17 | 20 | 22 |
---|---|---|---|---|---|
16mm x 1/2" Male Iron | 2 | 2 | 2 | 2 | 2 |
Isolation/Ball Valve | |||||
Clip Track | 18 | 23 | 26 | 30 | 33 |
Edge Insulation | |||||
Eurocones (16mm) | |||||
Fill & Drain Valves | |||||
Manifold Pump & Mixing Valve Unit | |||||
Single Circuit Pump & Mixing Valve | |||||
Manifold Ports | |||||
Pipe Length (m) | 50 | 60 | 70 | 80 | 90 |
Pipe Cutters | |||||
Pipe Rounding Tool | |||||
Thermostat | 1 | 1 | 1 | 1 | 1 |
Kit Size (m2) | 25 | 27 | 30 | 37 | 50 |
---|---|---|---|---|---|
16mm x 1/2" Male Iron | 2 | 2 | 2 | ||
Isolation/Ball Valve | |||||
Clip Track | 38 | 41 | 45 | 56 | 75 |
Edge Insulation | |||||
Eurocones (16mm) | 4 | 4 | |||
Fill & Drain Valves | |||||
Manifold Pump & Mixing Valve Unit | |||||
Single Circuit Pump & Mixing Valve | |||||
Manifold Ports | 2 | 2 | |||
Pipe Length (m) | 100 | 110 | 120 | 150 | 200 |
Pipe Cutters | |||||
Pipe Rounding Tool | |||||
Thermostat | 1 | 1 | 1 | 1 | 1 |
Kit Size (m2) | 62 | 75 | 87 | 100 |
---|---|---|---|---|
16mm x 1/2" Male Iron | ||||
Isolation/Ball Valve | ||||
Clip Track | 93 | 113 | 131 | 150 |
Edge Insulation | ||||
Eurocones (16mm) | 6 | 6 | 8 | 8 |
Fill & Drain Valves | ||||
Manifold Pump & Mixing Valve Unit | ||||
Single Circuit Pump & Mixing Valve | ||||
Manifold Ports | 3 | 3 | 4 | 4 |
Pipe Length (m) | 250 | 300 | 350 | 400 |
Pipe Cutters | ||||
Pipe Rounding Tool | ||||
Thermostat | 1 | 1 | 1 | 1 |
Kit Size (m2) | 12 | 15 | 17 | 20 | 22 | 25 | 27 |
---|---|---|---|---|---|---|---|
16mm x 1/2" Male Iron | 2 | 2 | 2 | 2 | 2 | 2 | 2 |
Isolation/Ball Valve | |||||||
Clip Track | 18 | 23 | 26 | 30 | 33 | 38 | 41 |
Edge Insulation | |||||||
Eurocones (16mm) | |||||||
Fill & Drain Valves | |||||||
Manifold Pump & Mixing Valve Unit | |||||||
Single Circuit Pump & Mixing Valve | |||||||
Manifold Ports | |||||||
Pipe Length (m) | 50 | 60 | 70 | 80 | 90 | 100 | 110 |
Pipe Cutters | |||||||
Pipe Rounding Tool | |||||||
Thermostat | 1 | 1 | 1 | 1 | 1 | 1 | 1 |
Kit Size (m2) | 30 | 37 | 50 | 62 | 75 | 87 | 100 |
---|---|---|---|---|---|---|---|
16mm x 1/2" Male Iron | 2 | ||||||
Isolation/Ball Valve | |||||||
Clip Track | 45 | 56 | 75 | 93 | 113 | 131 | 150 |
Edge Insulation | |||||||
Eurocones (16mm) | 4 | 4 | 6 | 6 | 8 | 8 | |
Fill & Drain Valves | |||||||
Manifold Pump & Mixing Valve Unit | |||||||
Single Circuit Pump & Mixing Valve | |||||||
Manifold Ports | 2 | 2 | 3 | 3 | 4 | 4 | |
Pipe Length (m) | 120 | 150 | 200 | 250 | 300 | 350 | 400 |
Pipe Cutters | |||||||
Pipe Rounding Tool | |||||||
Thermostat | 1 | 1 | 1 | 1 | 1 | 1 | 1 |
Kit Size (m2) | 12 | 15 | 17 | 20 | 22 | 25 | 27 | 30 | 37 | 50 | 62 | 75 | 87 | 100 |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
16mm x 1/2" Male Iron | 2 | 2 | 2 | 2 | 2 | 2 | 2 | 2 | ||||||
Isolation/Ball Valve | ||||||||||||||
Clip Track | 18 | 23 | 26 | 30 | 33 | 38 | 41 | 45 | 56 | 75 | 93 | 113 | 131 | 150 |
Edge Insulation | ||||||||||||||
Eurocones (16mm) | 4 | 4 | 6 | 6 | 8 | 8 | ||||||||
Fill & Drain Valves | ||||||||||||||
Manifold Pump & Mixing Valve Unit | ||||||||||||||
Single Circuit Pump & Mixing Valve | ||||||||||||||
Manifold Ports | 2 | 2 | 3 | 3 | 4 | 4 | ||||||||
Pipe Length (m) | 50 | 60 | 70 | 80 | 90 | 100 | 110 | 120 | 150 | 200 | 250 | 300 | 350 | 400 |
Pipe Cutters | ||||||||||||||
Pipe Rounding Tool | ||||||||||||||
Thermostat | 1 | 1 | 1 | 1 | 1 | 1 | 1 | 1 | 1 | 1 | 1 | 1 | 1 | 1 |
- Select a suitable location for the pump & manifold unit and mount on the wall.
- Clipping the 1m sections together to create one continous length space runs at 750mm spacing apart using the self adhesive backing to adhere to the floor.
- Lay the pipe as planned, fixing every 150mm or 200mm spacing depending on the system purchase, compressing pipe into the manufactured grippers.
- To lay the circuit, cut the pipe end squarely using the plastic pipe cutter, re-round the pipe end with the tool provided, place the nut over the pipe, ensure the olive and insert is fully fitted over the end of the pipe and the assembly is attached to the manifold. Tighten the nut using an open end spanner. Do not over tighten.
- Prevent people from walking on the pipes, keep tools etc away from the pipes and use running boards. The pipe is very tough, but it is better to be safe than sorry.
- It is IMPORTANT that the underfloor heating system is properly filled with water (use a garden hose) and purged completely of air to ensure correct operation. IT IS NOT ADEQUATE TO FILL THE SYSTEM USING THE BOILER FILLING LOOP!
Key Features
- Easy Installation:
- The clip rail track features a self-adhesive backing, allowing for quick and hassle-free installation. It can be securely mounted to the subfloor, providing a stable base for the pipework.
- Secure Pipework Fixing:
- Once the clip rail track is in place, the (15mm/16mm) pipework can be easily clipped into position, ensuring a secure and reliable fixing. This helps to prevent any movement or displacement of the pipework during and after installation.
- Optimal Heat Distribution:
- By securely holding the pipework in place, the clip rail track ensures that the warm water flows evenly throughout the underfloor heating system. This results in efficient and consistent heat distribution across the entire floor surface.
- Quantity Calculation:
- The required quantity of clip rail track can be easily determined by multiplying the area in square meters (m2) by 1.5. For example, if you have a floor area of 30m2, you would need 45 clip rail lengths to cover the entire space.
Free Delivery as Standard!
As standard we include 2 - 3 working day delivery on all orders delivered to the UK mainland. * A £5 delivery charge will be applied to all orders below £20.
Delivery cut off times
Our final delivery time for Mondays to Thursday is 4:30pm. To give us a bit more time to ensure weekend deliveries are handled and our couriers have time to collect, the final delivery time on Fridays is 4:00pm.
2-3 working day delivery
Next working day
Next working day before 10:30
Saturday Delivery
* A £5 delivery charge will be applied to all orders below £20.
Other Delivery Options
Pre 10:30am and Saturday delivery services are available on orders placed before 4:30pm. Any order placed before 4:30pm on a Friday will be delivered on the following Monday (unless its a bank holiday) so please select a Saturday service if a weekend delivery is required.
Delivery outside the UK
Delivery outside the mainland UK may be arranged by prior agreement. You will be notified of the amount of the charge for this service and will at that point have to make a decision whether you wish to proceed wth your order.
Important: Our deliveries rely on third party couriers, so, whilst we make every effort to deliver your order on the specified date and time, unfortunately there may be occasions when this will not be possible due to external influences. Due to this we strongly recommend you ensure you have received your order before any tradespeople/builders are scheduled to commence work.
Still Unsure? Talk to an expert
If you need any guidance or further information our highly experienced team are on hand to help.
Get in touch using our contact form or give us a call on 0800 023 4203 or 01268 744 479.