How to Fit Large Areas?

Our guide on installing Underfloor Heating in large areas

Electric Underfloor Heating for Large Areas

Fastwarm® electric underfloor heating systems are limited to the maximum switch load of the thermostat. Thermostats for electric underfloor heating including our Fastwarm® range are limited to a maximum of 16amps or 3600watts.

This portrays into the below area coverages using a 3 different type of systems:

Fastwarm Underfloor Heating Sticky Mat
Fastwarm® Sticky Mat

Fastwarm® Sticky mats are pre spaced out cables on a sticky mesh matting. These systems are supplied in 3 different outputs per m2.

36m2
100w Sticky Mat
24m2
150w Sticky Mat
18m2
200w Sticky Mat
Fastwarm Underfloor Heating Loose Cable
Fastwarm® Loose Cable

Fastwarm® loose cables are supplied in a standard 10w per linear meter output and the wattage per meter squared are determined by the spacings create when laying the system. Totalling 360m of cable maximum per 1 thermostat.

200w m2
50mm spacing
150w m2
65mm spacing
100w m2
100mm spacing
Fastwarm Underfloor Heating Foil Mat
Fastwarm® Foil Mat

Fastwarm® Foil mats are a multi used system supplied with both the underwood systems and the Fastwarm® Under Carpet / vinyl system when cover with heat pak dual overlay. This system runs at 140w per meter squared.

200w m2
140w Foil Mat

Is your floor area larger than the maximum kit size? We have 2 options:

OPTION 1
Install a contactor which will aid in switching the greater load, these are available in 25A and 40A. You need to ensure that your electrician is able to run suitable direct supply to power the system. A contactor is a switch capable of switching high loads. your thermostat would switch this on rather than the heating. All the heating power supplies run back to the contactor position.
OPTION 2
Split the area into multiple zones / smaller areas incorporating 2 or more thermostats.
Shop Electric Underfloor Heating
Talk to an expert.
If you would like to discuss any aspect of your underfloor heating project, our team are more than happy to help.

Water Underfloor Heating for Large Areas

Fastwarm water underfloor heating systems are limited to a maximum single length of pipe on a single circuit pump. If the system requires over this set length of run of pipe, then a manifold will be introduced.

16mm diameter diagram
Fastwarm® 16mm Pipe

The maximum single pipe length is 120m. Beyond this length required a manifold.

18m2
150mm spacing
24m2
200mm spacing
30m2
250mm spacing
12mm diameter diagram
Fastwarm® 12mm Pipe

The maximum single pipe length is 80m. Beyond this length requires a manifold.

12m2
150mm Spacing

Can I control my manifold with 1 thermostat?

Although you will have multiple runs of pipe into 1 room this wouldn’t require multiple thermostats. The manifold would be set up to allow a flow of water into the specific pipes for this area, if composed of more than one room / zone then a second and possibly third thermostat will be added resulting in you single zone system being turned into a multi zone system.

This type of installation will include actuators and a underfloor heating wiring centre.

Shop Water Underfloor Heating
Talk to an expert.
If you would like to discuss any aspect of your underfloor heating project, our team are more than happy to help.